This blog mainly consist of COMPUTER HARDWARE,NETWORKING as well as SOFTWARE Troubleshooting.
Friday, August 7, 2009
Disable/Enable start menu
Click START–>RUN and type REGEDIT. Click OK.
Click the plus sign next to HKEY_CURRENT_USERthen SOFTWAREthen Microsoftthen Windowsthen CurrentVersionthen Policiesthen Explorer
Double-click on NoSimpleStartMenu if it exists.
If it doesn’t, right-click on ADVANCED and Select NEW–>DWORD VALUE and name it NoSimpleStartMenu
Set this value to 1 to disable the XP menu.
This setting will permanently disable the Windows XP style Start Menu unles the policy or registry is changed.
Thursday, August 6, 2009
Settings Tab Missing - Display Properties
***The Group Policy Editor requires Administrative privileges and is only available for Windows XP Professional Edition. Windows XP Home users can use the Windows XP Registry way to remove the Group Policy restriction.***
- Click Start and then Run.
- Type gpedit.msc in the Run dialog box.
- Press ENTER on your keyboard.
- In the Group Policy Editor navigate to:User Configuration > Administrative Templates > Control Panel > Display
- Double-click Hide Settings tab.
- Select Not Configured.
***If the Settings tab is missing on a per User account basis then the above method will not work, you will need to use the Registry Editor to remove the Group Policy.***
Manual Steps Using Windows XP Registry
- Click Start and then Run.
- Type regedit.exe in the Run dialog box.
- Press ENTER on your keyboard.
Navigate to:HKCU\Software\Microsoft\Windows\CurrentVersion\Policies\System
Right-click NoDispSettingsPage to select Modify. - Change the value to 0.
- Navigate to:HKLM\Software\Microsoft\Windows\CurrentVersion\Policies\System
Right-click NoDispSettingsPage to select Modify. - Change the value to 0.
- Quit the Registry Editor (Regedit.exe).
***You may need to log off then log on to your user account or restart your computer for the changes to take affect.***
Manual Steps Using REG ADD
- Open a Command Window.
Type:REG ADD "HKCU\Software\Microsoft\Windows\CurrentVersion\Policies\System" /v NoDispSettingsPage /t REG_DWORD /d 0 - Press ENTER on your keyboard.
Type:REG ADD "HKLM\Software\Microsoft\Windows\CurrentVersion\Policies\System" /v NoDispSettingsPage /t REG_DWORD /d 0 - Press ENTER on your keyboard.
- Type EXIT and press ENTER on your keyboard.
***You may need to log off then log on to your user account or restart your computer for the changes to take affect.***
Wednesday, August 5, 2009
Screen Saver Timeout Restricted - Display Properties
Windows XP Screen saver timeout numeric box located in the Display Properties under the Screen Saver tab is restricted/disabled .The most likely cause of this is malware utilizing Group Policy Objects which enforces policies for system settings and/or user account(s) settings. The Group Policy for Screen Saver timeout will cause the Screen saver timeout numeric box to be restricted/disabled in Display Properties when enabled.
Group Policies are typically applied at businesses to control access to programs, system properties, and user account settings. For Home users, Screen saver timeout numeric box can be restricted/disabled by these Group Policies but usually malware is the culprit. If you are a home user and the Screen saver timeout numeric box is restricted/disabled from the Display Properties and looks like the pictures below then there is a good chance you are infected with malware.
Manual Steps : Using Group Policy Editor
NOTE: The Group Policy Editor requires Administrative privileges and is only available for Windows XP Professional Edition. Windows XP Home users can use the Windows XP Registry method to remove the Group Policy restriction.
- Click Start and then Run.
- Type gpedit.msc in the Run dialog box.
- Press ENTER on your keyboard.
- In the Group Policy Editor navigate to:User Configuration > Administrative Templates > Control Panel > Display
- Double-click Screen Saver Timeout.
- Select Not Configured.
- *** If the Screen saver timeout numeric box is restricted/disabled on a per User account basis then the above method will not work, you will need to use the Registry Editor to remove the Group Policy. ***
Manual Steps : Using Windows XP Registry
- Click Start and then Run.
- Type regedit.exe in the Run dialog box.
- Press ENTER on your keyboard.
Navigate to:HKCU\Software\Policies\Microsoft\Windows\Control Panel\Desktop
Right-click ScreenSaveTimeOut to select Delete. - Navigate to:HKLM\Software\Policies\Microsoft\Windows\Control Panel\Desktop
Right-click ScreenSaveTimeOut to select Delete. - Quit the Registry Editor (Regedit.exe).
*** You may need to log off then log on to your user account or restart your computer for the changes to take affect.***
Manual Steps : Using REG DELETE
- Open a Command Window.
- Type:REG DELETE "HKCU\Software\Policies\Microsoft\Windows\Control Panel\Desktop" /v ScreenSaveTimeOut /f
- Press ENTER on your keyboard.
Type:REG ADD "HKLM\Software\Policies\Microsoft\Windows\Control Panel\Desktop" /v ScreenSaveTimeOut /f - Press ENTER on your keyboard.
- Type EXIT and press ENTER on your keyboard.
Tuesday, August 4, 2009
Network Cable Types
The three main types of networking cables are coaxial cable, twisted-pair cable and fiber optic cable.

Coaxial cable is made of two conductors that share the same axis; the center is a copper wire that is insulated by a plastic coating and then wrapped with an outer conductor (usually a wire braid). This outer conductor around the insulation serves as electrical shielding for the signal being carried by the inner conductor. A tough insulating plastic tube outside the outer conductor provides physical and electrical protection. At one time, coaxial cable was the most widely used network cabling. However, with improvements and the lower cost of twisted-pair cables, it has lost its popularity.
- ThickNet
- ThinNet
ThickNet is about .38 inches in diameter. This makes it a better conductor, and it can carry a signal about 1640 feet (500 meters) before signal strength begins to suffer. The disadvantage of ThickNet over ThinNet is that it is more difficult to work with. The ThickNet version is also known as standard Ethernet cable.
ThinNet:
ThinNet is the easiest to use. It is about .25 inches in diameter, making it flexible and easy to work with (it is similar to the material commonly used for cable TV). ThinNet can carry a signal about 605 feet (185 meters) before signal strength begins to suffer.
10Base2 ThinNet Coaxial 185 meters 10 Mbps
10Base5 ThickNet Coaxial 500 meters 10 Mbps
Coaxial cable can only be used with a BNC (bayonet-Neill-Concelman) connector.
Twisted-pair cable consists of two insulated strands of copper wire twisted around each other to form a pair. One or more twisted pairs are used in a twisted-pair cable. The purpose of twisting the wires is to eliminate electrical interference from other wires and outside sources such as motors. Twisting the wires cancels any electrical noise from the adjacent pair. The more twists per linear foot, the greater the effect.
There are two types of twisted pair cable.
- Shielded Twisted Pair (STP)
- Unshielded Twisted Pair (UTP)
Shielded Twisted Pair (STP):
The only difference between STP and UTP is that STP has a foil or wire braid wrapped around the individual wires of the pairs. The shielding is designed to minimize EMI radiation and susceptibility to crosstalk. The STP cable uses a woven-copper braided jacket, which is a higher-quality, more protective jacket than UTP.
Unshielded Twisted Pair (UTP):
As the name implies, "unshielded twisted pair" (UTP) cabling is twisted pair cabling that contains no shielding. UTP cables can be divided further into following categories:
Category 1:-Traditional telephone cable. Carries voice but not data
Category 2:-Certified UTP for data transmission of up to 4 megabits per second (Mbps). It has four twisted pairs
Category 3:-Certified UTP for data transmission of up to 10 Mbps. It has four twisted pairs
Category 4:-Certified UTP for data transmission of up to 16 Mbps. It has four twisted pairs
Category 5:-Certified for data transmission of up to 100 Mbps. It has four twisted pairs of copper wire
Category 6:-Offers transmission speeds up to 155 Mbps
Category 7:-Category 7 is a proposed standard that aims to support transmission at frequencies up to 600 MHz
Twisted-pair cable has several advantages over other types of cable (coaxial and fiberoptic): It is readily available, easy to install, and inexpensive. Among its disadvantages are its sensitivity to electromagnetic interference (EMI), its susceptibility to eavesdropping, its lack of support for communication at distances of greater than 100 feet, and its requirement of a hub (multiple network connection point) if it is to be used with more than two computers. Twisted pair cables use RJ45 connector.
Name Description Type Segment Speed
10BaseT 100BaseT UTP .5 to 100 meters 10 Mbps
100BaseT common Twisted-pair .5 to 100 meters 100 Mbps
Fiber optic Cable:
Fiberoptic cable is made of light-conducting glass or plastic fibers. It can carry data signals in the form of modulated pulses of light. The plastic-core cables are easier to install but do not carry signals as far as glass-core cables. Multiple fiber cores can be bundled in the center of the protective tubing.
When both material and installation costs are taken into account, fiberoptic cable can prove to be no more expensive than twisted-pair or coaxial cable. Fiber has some advantages over copper wire: It is immune to EMI and detection outside the cable and provides a reliable and secure transmission media. It also supports very high bandwidths (the amount of information the cable can carry), so it can handle thousands of times more data than twisted-pair or coaxial cable.Cable lengths can run from .25 to 2.0 kilometers depending on the fiberoptic cable and network. If you need to network multiple buildings, this should be the cable of choice. Fiberoptic cable systems require the use of fiber-compatible NICs.